CTC activity is the weight a sample of activated carbon gains, in per cent, when it is saturated with carbon tetrachloride vapour (ASTM D3467). It measures how much vapour the carbon’s small pores can hold. Because carbon tetrachloride is an ozone-depleting substance, butane activity (ASTM D5742) is now widely used in its place.

What the CTC test measures

In ASTM D3467, dry air carrying carbon tetrachloride vapour is passed through a weighed bed of granular carbon until the carbon stops gaining weight. The weight gained, divided by the weight of the carbon, is the CTC activity in per cent. Like the iodine number, it reflects the volume of micropores, but it is measured in the gas phase rather than in solution, so it is the usual activity measure for carbon used in air and gas treatment and appears in many specifications for gold-recovery carbon.

Why fewer laboratories run it

Carbon tetrachloride is controlled under the Montreal Protocol, and many laboratories no longer handle it. ASTM itself presents butane activity as a substitute: ASTM D5742 states that the butane activity test can be used as a non-ozone-depleting substitute for the carbon tetrachloride activity test in D3467, and the standard includes an experimental correlation between the two. In practice this means that a buyer who specifies CTC may be offered a butane activity result, converted using a correlation agreed between buyer and seller.

Butane activity (ASTM D5742)

Butane activity is the mass of butane adsorbed by the carbon, as a percentage of the carbon’s mass, when it is saturated with butane under the conditions of the standard. It is also an indication of micropore volume. The standard was written for granular carbon; powdered carbon needs adjusted flow conditions.

How to read CTC in a specification

CTC in gold recovery and gas treatment

In gas-phase applications, CTC or butane activity directly indicates how much organic vapour the carbon can hold before breakthrough. In gold recovery, activity affects how fast and how much gold cyanide the carbon loads, but most plants also run their own gold-adsorption tests on a sample before approving a new carbon. Our gold-recovery GAC 6×12 is specified at CTC min 55–60%; our published independent reports cover iodine number and hardness, and CTC testing can be arranged for an order.

Test it yourself

For the methods behind every parameter and our independent results, see Quality Control & Laboratory Testing and the full reports on our certification page. To check our carbon in your own laboratory, request a sample with its certificate of analysis.