A mesh size such as 6×12 means the carbon passes a US No. 6 sieve (3.35 mm) and is retained on a No. 12 sieve (1.70 mm). Particle size distribution is measured by sieve analysis (ASTM D2862). The right size depends on the process: gold plants use coarse grades such as 6×12 to suit their screens, while water filters commonly use 8×30 or 12×40.
Mesh designations in millimetres
| Grade | Upper sieve | Lower sieve | Typical use |
|---|---|---|---|
| 4×8 | No. 4 = 4.75 mm | No. 8 = 2.36 mm | Air and gas treatment, low pressure drop |
| 6×12 | No. 6 = 3.35 mm | No. 12 = 1.70 mm | Gold recovery (CIP / CIL) |
| 8×30 | No. 8 = 2.36 mm | No. 30 = 0.60 mm | Drinking water and wastewater filters |
| 12×40 | No. 12 = 1.70 mm | No. 40 = 0.425 mm | Water filters, point-of-use cartridges |
| 30×60 | No. 30 = 0.60 mm | No. 60 = 0.25 mm | Cartridges, fine filtration |
How particle size is tested (ASTM D2862)
A sample is shaken through a stack of sieves for a set time, and the carbon on each sieve is weighed. The result shows how much of the sample is oversize, within the nominal range and undersize. Specifications usually allow a few per cent outside the nominal range, for example a maximum of 5% oversize and 5% undersize.
Effective size and uniformity coefficient
Water treatment specifications, such as AWWA B604, often add two figures calculated from the sieve curve: the effective size (the opening through which 10% of the carbon passes) and the uniformity coefficient (the ratio of the 60% opening to the 10% opening). A lower uniformity coefficient means more evenly sized granules and more predictable backwashing.
Choosing a size
- Gold recovery. The carbon must be coarse enough to stay behind the interstage screens and hard enough not to break into fines that pass through. 6×12 is the most common size. See activated carbon for gold recovery.
- Water treatment. Finer carbon adsorbs faster because diffusion paths are shorter, but raises pressure drop. 8×30 is a common balance for gravity and pressure filters. See activated carbon for water treatment.
- Air and gas. Coarse grades such as 4×8 keep pressure drop low in deep beds.
- Powdered carbon. PAC is specified by the share passing a fine sieve, such as 200 or 325 mesh, and is dosed into liquid and filtered out rather than used in a fixed bed.
Test it yourself
For the methods behind every parameter and our independent results, see Quality Control & Laboratory Testing and the full reports on our certification page. To check our carbon in your own laboratory, request a sample with its certificate of analysis.
Related guides: Empty Bed Contact Time (EBCT) for GAC Filters: Formula and Typical Values